Solar panel and battery calculator

Estimate array size and battery bank capacity from daily energy use.

Use the figure for the worst season you need to cover.

Covers wiring, inverter, heat and dirt losses.

Array size needed
3.33333 kW
Panels needed
9 × 400 W
Installed array
3.6 kW
Battery bank (nominal)
13.8889 kWh
Battery capacity at 48 V
289.352 Ah

Formula

Array kW = daily kWh / (sun hours × efficiency). Battery kWh = daily kWh × days / (DoD × round-trip efficiency). Ah = kWh × 1000 / V

Efficiency, depth of discharge (DoD) and round-trip efficiency are entered as percentages and used as fractions.

Diagram

Solar and battery sizingSunArrayBatteryLoadArray kW = daily kWh / (sun hours × efficiency)Battery kWh = daily kWh × days / (DoD × round-trip efficiency)Battery Ah = battery kWh × 1000 / bank voltageDoD = share of battery capacity you allow to be used
Daily energy use sets the array size through peak sun hours and losses, and sets the battery size through autonomy days and usable depth of discharge.

How it is calculated

  1. Divide daily energy use by (peak sun hours × system efficiency) to get the array size in kW.
  2. Divide the array size by one panel's rating and round up to get the number of panels.
  3. Multiply daily energy use by the days of autonomy for the energy the battery must supply.
  4. Divide by (depth of discharge × round-trip efficiency) for the nominal battery size in kWh.
  5. Divide the kWh by the bank voltage and multiply by 1,000 to get amp-hours.

Use the peak sun hours for your worst season if the system must work all year.

Worked examples

  1. A small cabin

    10 kWh a day, 4 sun hours, 75% efficiency, 400 W panels, 1 day of autonomy at 48 V. Result: Array size needed: 3.33333 kW; Panels needed: 9 × 400 W; Battery bank (nominal): 13.8889 kWh; Battery capacity at 48 V: 289.352 Ah.

  2. A sunny site, low use

    5 kWh a day with 5 sun hours. Result: Array size needed: 1.33333 kW; Panels needed: 4 × 400 W; Battery bank (nominal): 6.94444 kWh.

  3. A larger off-grid home

    30 kWh a day, 3.5 sun hours and 2 days of autonomy at 48 V. Result: Array size needed: 11.4286 kW; Panels needed: 29 × 400 W; Battery bank (nominal): 83.3333 kWh; Battery capacity at 48 V: 1,736.11 Ah.

Key terms

Peak sun hours
The daily solar energy at your site, in kWh per square metre, expressed as hours of full 1 kW/m² sunlight.
System efficiency
The share of panel output that reaches your loads after wiring, inverter, heat and dirt losses.
Days of autonomy
How many days the battery must run your loads with no solar input.
Depth of discharge (DoD)
The share of battery capacity you allow to be used. Limiting it protects battery life, and the safe level depends on the battery type.
Round-trip efficiency
Energy you get out of a battery divided by the energy put in.
Amp-hours (Ah)
A battery's charge capacity. Energy equals Ah times voltage.

Assumptions and limits

A simplified off-grid estimate. It ignores seasonal variation, panel tilt and shading, inverter and charge-controller limits, string design and battery temperature. System design and installation must follow local electrical code and be done by a qualified person. See the disclaimer.