A pump needs power to lift fluid and to overcome friction. Two numbers matter most: the flow you need and the total head the pump must produce.

Pump powerSource tankDelivery tankPShaft power inFlow QTotal head Hlift + frictionP_hydraulic = ρ × g × Q × H P_shaft = P_hydraulic / η
The pump lifts flow Q through total head H. Shaft power is the hydraulic power divided by pump efficiency.

Hydraulic power

Hydraulic power is the useful power delivered to the fluid: P = ρ × g × Q × H. Here ρ is density, g is gravity, Q is flow and H is total head.

Moving 10 m³/h of water against 30 m of head takes about 0.82 kW.

What counts as total head

Total head adds the static lift between the fluid levels, the friction losses in pipes and fittings, and any pressure required at the delivery point.

Shaft power and efficiency

Pumps lose energy to friction and leakage. Shaft power is hydraulic power divided by efficiency, so at 65% efficiency the example needs about 1.26 kW.

Choosing the motor

Motors are normally sized above the calculated shaft power to allow for margin, and the pump should operate near its best efficiency point on the pump curve. Always follow the manufacturer's data.