Pump Affinity Laws Explained: How Speed and Impeller Size Change Flow, Head and Power
Last reviewed 2026-10-17
If you change how fast a pump spins, or trim its impeller, its performance changes in a predictable way. The affinity laws describe that change and explain why slowing a pump saves so much energy.
The three laws
For the same pump and liquid, with r = N₂ / N₁ (the speed ratio): flow Q₂ = Q₁ × r, head H₂ = H₁ × r², and shaft power P₂ = P₁ × r³. Flow follows speed, head follows speed squared and power follows speed cubed.
Why power changes so fast
Because power depends on the cube of speed, a small slowdown has a large effect. Running a pump 20% slower (r = 0.8) cuts flow to 80%, head to 64% and power to 51%. That is why variable speed drives can save large amounts of energy on pumps that do not need full flow all the time.
Speeding a pump up
The same cube law works against you. Raising speed from 1,450 to 1,750 RPM (r = 1.207) lifts power by 76%. A pump giving 100 m³/h at 30 m and 5.5 kW then gives 120.7 m³/h at 43.7 m and needs about 9.67 kW, which may overload the motor.
Impeller trimming
The same laws apply approximately when you machine an impeller to a smaller diameter at constant speed. Trimming from 200 to 180 mm (r = 0.9) gives 90% of the flow, 81% of the head and 73% of the power. The approximation is best for modest trims, so follow the pump maker's curves.
Where the laws stop working
Efficiency changes a little with speed and diameter. A system with a large static head does not follow the simple ratios, because the pump has to overcome that fixed lift before it moves any water. A pump must never run above its rated speed, power or pressure, and the NPSH it requires also rises with speed.
A mental check
Think of a friction-only system, such as a closed loop. Its required head rises with the square of flow, and a pump's head also scales with speed squared, so the operating point moves along the system curve and the ratios hold well. Add a big static lift and they do not.
Common mistakes
Applying the laws to a different pump or a different liquid. Forgetting that the motor must handle the new power. Ignoring suction conditions when speeding up. Using the laws for large trims without checking the pump curve.
Try the calculators
Pump affinity laws calculator
Predict new flow, head and power after a speed or impeller change.
Pump power calculator
Estimate the power a pump needs for a given flow and head.
NPSH available calculator
Check whether a pump has enough suction head to avoid cavitation.
Pipe friction loss calculator
Find the head loss and pressure drop in a water pipe.