Pipe friction loss calculator
Find the head loss and pressure drop in a water pipe.
Optional. Overrides the material.
From 1 to 99 °C.
Optional. Adds minor losses K × v²/2g.
- Velocity
- 0.63662 m/s (2.08865 ft/s)
- Reynolds number
- 63,421.2 (turbulent)
- Friction factor f
- 0.021532
- Pipe friction head loss
- 0.444928 m (1.45974 ft)
- Pressure drop
- 4.35544 kPa (0.631704 psi)
- Loss per 100 m of pipe
- 0.444928 m
Formula
h_f = f × (L / D) × v² / 2g, Re = v × D / ν, Hazen-Williams: h_f = 10.67 × L × Q^1.852 / (C^1.852 × D^4.8704)f is the Darcy friction factor, found from the Colebrook equation for turbulent flow and 64 / Re for laminar flow. v is velocity, D the inside diameter, L the length, ν the kinematic viscosity of water at your temperature and g is 9.80665 m/s². Pressure drop = ρ × g × head loss. Hazen-Williams uses SI units: Q in m³/s, D and L in metres.
Diagram
How it is calculated
- Convert flow to m³/s and diameter and length to metres. Velocity is v = Q / A.
- Darcy-Weisbach: look up the water density and viscosity at your temperature, then find the Reynolds number Re = v D / ν.
- Find the friction factor f: 64 / Re for laminar flow, or the Colebrook equation (solved by iteration) for turbulent flow.
- Head loss h_f = f × (L / D) × v² / 2g. Add K × v² / 2g for fittings.
- Pressure drop = ρ × g × head loss. Hazen-Williams skips f and uses h_f = 10.67 × L × Q^1.852 / (C^1.852 × D^4.8704).
Doubling the flow roughly quadruples the friction loss in turbulent flow, and a smaller pipe is far more costly in pumping energy than a slightly larger one.
Worked examples
A typical water line
300 L/min of 20 °C water in a 100 mm commercial steel pipe, 100 m long: v = 0.64 m/s, Re = 63,421, f = 0.0215. Head loss is 0.445 m, which is a 4.36 kPa pressure drop.
Halve the diameter
The same flow in a 50 mm pipe runs at 2.55 m/s and loses 14.1 m (138 kPa). That is about 32 times more loss, because friction head falls with roughly the fifth power of the diameter.
Hazen-Williams for comparison
With C = 130 in the original 100 mm pipe, Hazen-Williams gives 0.527 m. The two methods are empirical and differ by a few tenths of a metre here, so pick one and stay consistent.
Key terms
- Head loss
- Energy lost to friction, expressed as a height of liquid. 10 m of water head is about 98 kPa.
- Reynolds number (Re)
- A ratio of inertial to viscous forces. Below about 2,000 flow is laminar and above about 4,000 it is turbulent.
- Friction factor (f)
- A dimensionless number that depends on Re and on the relative roughness of the pipe wall.
- Relative roughness
- The wall roughness ε divided by the diameter D.
- Kinematic viscosity (ν)
- A liquid's resistance to flow divided by its density. Water gets thinner as it warms.
- Minor loss (K)
- Extra loss at fittings, valves and bends, written as a K value times v² / 2g.
- Hazen-Williams C
- An empirical smoothness factor for water pipes. A higher C means less friction.
Assumptions and limits
Water only, full pipe, steady flow. Roughness values are typical and rise with age and scale. The transitional range (Re 2,000 to 4,000) is uncertain. Hazen-Williams is an empirical formula for water at ordinary temperatures in turbulent flow. Confirm important designs with a qualified engineer. See the disclaimer.